What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE ACCESS PANEL NR 62 FWD MOST COMPTARTMENT, RT SIDE BOTTOM ANGLE OF FWD BULKHEAD, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED ANGLE & SHIMS FROM 7075-T6 AND INSTALLED IAW DC-8 SRM 51-1-4, 51-1-21, 53-2-0 AND E.O. NR 99-236 WITH APPROVED 8110-3 DATED 2-17-00.