What was found
DURING A MAINTENANCE VISIT FOUND CHAFFING AT THE LT AFT FILLET WEB AT FUSELAGE STA 920, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, ALODINED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR FROM 7075-T6 AND INSTALLED IAW DC-8 SRM 51-1-21 AND E.O. NR 99-236 WITH APPROVED 8110-3 DATED 2-15-00.