What was found
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES TO THE SEAT TRACK C1-R4 IN THE UPPER CARGO COMPT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED SEAT TRACK FROM 60-12809 AND INSTALLED IAW ROSENBALM DWG 24300, DC-8 SRM 51-3-0, 53-2-3 AND E.A. 77-N994CF.