What was found
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE INTERCOSTAL ATTACH ANGLES AT FUSELAGE STA 460 TO 400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED ANGLE FROM 7075-T6 AND INSTALLED IAW DC-8 SRM 53-2-0 AND 51-1-20D.