What was found
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES TO THE TOP FLOORBEAM AT FWD. UPPER CARGO COMPT. STA 380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM. PLUGGED ALL DISCREPANT HOLES, FABRICATED DOUBLERS FROM 7075-T6 AND INSTALLED PER E.O. 99-236 WITH APPROVED 8110-3 DATED 12-17-99.