What was found
DURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FWD. CARGO COMPT TOP OF FLOOR BEAM AS STA 270, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED DOUBLERS FROM 7075-T6 AND INSTALLED IAW E.O. 99-236 WITH APPROVED 8110-3 DATED 12-*17-99.