What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE FWD LOWER CARGO COMPARTMENT RIGHT STIFFENER AT STA 550 TO 560 AND L32R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW STIFFENER IAW DC-8 SRM 51-1-20D. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).