What was found
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 640 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES, FABRICATED STRAP FROM 7075-T6 AND INSTALLED IAW DC-8 SRM 51-1-21, 53-2-0 AND EO NR 99-236 WITH APPROVED 8110-3 DATED 12-02-99.