What was found
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 920 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED AND DISCREPANT HOLES, FABRICATED DOUBLER FROM 7075-T6 AND INSTALLED PER EO 99-236 WITH APPROVED 8110-3 DATED 12-03-99.