What was found
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 540 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT AND MISDRILLED HOLES PER EO NR 99-236 WITH APPROVED 8110-3 DATED 12-01-99.