What was found
NR 4 ENGINE FLAME OUT ON T/O MMMX. ON ENGINFLIGHT START CHECKLIST NR 4 ENG LIT OFF & STAGNATED AT APPROX 320DEG C. THEN FAMED OUT AGAIN. PERFORMED INFLIGHT SHUTDOWN CHECKLIST. NR 4 ENG. R&R'D BY G.E. ON-WING IAW MM 71-00-42. ENG. CHECKED GOOD , OPS. CHECKED IAW FUNCTIONAL TEST RUN MM71-00-00. ALL PARAMETERS NORMAL AT ALL POWER SETTINGS IAW EWA AIRCRAFT MM CHPT. 12. NO DEFECTS NOTED.