SDR RRXA001097

Service difficulty report · Cooler · Doug DC873F

Difficulty date
December 22, 2000
Submitted
January 19, 2001
Operation
Air carrier
Aircraft
N870TV
Make and model
Doug DC873F
Aircraft serial
46086
Aircraft time
83,780 hours, 26,974 cycles
Part
Cooler
Part number
9799084
Part serial
P414CP635C
Condition
Failed
Location
Nr 1 & Nr 2 Eng
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
E, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

TOP OF CLIMB, LT MANIFOLD TEMP INCREASED UNTIL NR 2 MAN AIR TEMP LIGHT CAME ON TEMP AT 265, NR 2 HIGH STAGE LIGHT ON. TURNED NR 2 BLEED OFF, MANIFOLD TEMP MOMENTARILY DECREASED THEN NR 1 MAN AIR TEMP LIGHT CAME ON. CYCLED TO MAINTAIN CABIN. BOTH NR 1 & 2 BLEED OFF TO MAINTAIN TEMP. REMOVED AND REPLACED NR 1 AND 2 ENGINES PRECOOLER VALVES PER MM 36-12-58. SYSTEMS FUNCTION NORMALLY.