What was found
DURING A MAINTENANCE VISIT, FOUND A LARGE HOLE 9 INCHES FROM EDGE, 5 INCHES FROM OUTBOARD EDGE C12-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCOMPLISHED WELD REPAIR PER E.O. 99-236 WITH APPROVED 8110-3 DATED 3-6-00.