What was found
DURING A MAINTENANCE VISIT, FOUND A HOLE DRILLED IN RADIUS OF INTERCOSTAL IN THE CABIN UPPER CARGO COMPT. AT FS 1280 TO 1300 AND LONG. 14L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW DC-8 SRM 53-2-0 AND 51-1-21.