What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AND SCREWS PULLING THROUGH SKIN AT LT IB NR 2 STUB WING AT STA XFS 250 TO 291, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 57-2-0, 51-1-21, 51-1-20D AND E.O. 00-055 WITH APPROVED 8110-3 DATED 3-22-00.