What was found
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CAPT''S RT AFT SEAT TRACK LOCK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED TRACK IAW DC-8 SRM 51-3-0, 53-2-0 AND 51-1-24.