What was found
DURING A MAINTENANCE VISIT FOUND A DRILL START IN RADIUS OF SHEAR FOOT AT STA 1280, 3 INCHES UP FROM L21R CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED DRILL START SMOOTH IAW EO NR 00-055 WITH APPROVED 8110-3 DATED 3-16-00.