As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A MAINTENANCE VISIT FOUND THE AFT MOUNT BOLT RETAINERS ARE TOO SHORT (DO NOT FIT OVER BOLT), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW MOUNT BOLT IAW DC-8 SRM 51-3-0, 72-22-0 AND EO NR 00-055 WITH APPROVED 8110-3 DATED 4-11-00.