What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AROUND THE SCREW HOLES AT THE LT WING I/B LEADING EDGE UPPER SURFACE SKIN AT STA XFS 113.750 TO XFS 10.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 57-2-0 AND EO NR 00-055 WITH APPROVED 8110-3 DATED 3-16-00. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).