As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A MAINTENANCE VISIT FOUND ALL 4 AFT MOUNT BOLT RETAINERS ARE TOO SHORT AND DO NOT FIT OVER BOLT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED BOLTS IAW DC-8 SRM 51-3-0, MM 72-00-00 AND EO NR 00-055 WITH APPROVED 8110-3 DATED 4-11-00.