What was found
DURING A MAINTENANCE VISIT FOUND HOLES TO THE INTERCOSTAL IN THE UPPER CARGO COMPT. AT FS 798 TO 822 AND L5L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-20D