What was found
DURING A MAINTENANCE VISIT FOUND ABOUT A 1.5 INCH CRACK IN SKIN AND 9 FASTENERS BAD ON THE LEFT L/E AT STA XFS 422, 9 INCHES FROM FRONT SPAR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-107 WITH APPROVED 8110-3 DATED 5-10-00.