What was found
DURING A MAINTENANCE VISIT FOUND A TORN SIDEWALL ATTACH FRAME IN CARGO PIT (INTERCOSTAL) AT FS 500 - 520 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0, 51-1-4 AND 51-1-21.