What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FWD LWR CARGO BILGE AT STA 350 AND L35R LT SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0, 53-2-2 AND 51-1-20D. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).