What was found
DURING A MAINTENANCE VISIT FOUND A PUNCTURE TO THE STRUCTURE AT O/B END OF NR 2 GROUND SPOILER LT WING AT STA XRS 162.263 (NOT SPOILER), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21, 53-2-0.