What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND SCREWS BROKEN OFF IN TRACK FLANGE AT STA Y=620-717 AND X=+25, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0, TMS 60-6549 FROM STC SA 180250 AND DWG#86302. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).