What was found
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE BULKHEAD MIDDLE RT SUPPORT (HORIZONTAL) AT STA 70, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-4.