What was found
DURING A MAINTENANCE VISIT FOUND A SMALL DOUBLER CRACKED ON THE RIGHT O/B, I/B FLAP SCISSOR AREA LWR SURFACE AFT CORNER OF RIB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 51-1-4 AND 51-1-21.