What was found
DURING A MAINTENANCE VISIT FOUND A CRACK IN LOWER SPAR CAP, WEB AND SKIN LOWER ON LEFT WING AT STA XFS 576, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DWG 5802712, 5803975 AND EA PD 28-59-039.