What was found
DURING A MAINTENANCE VISIT FOUND WORN AND ELONGATED HOLES TO THE F/O'S RIGHT AFT SEAT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0, 53-2-3 FIG.11.