What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE INTERCOSTAL STRAP OVER FRAME AT STA 1080 ABOVE L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0, 51-1-4, 51-1-24, 51-1-21 AND 51-1-20D FIG 1F. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).