What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE L/H HORIZONTAL STABILIZER JACK SCREW AT STA 1800 X=24 Z=35, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 MM 27-41-1.