What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SEAT TRACK AROUND FASTENERS AT FS 120-140 AND L30R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2-0.