What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SEAT TRACK HARDWARE AT STA 680 THROUGH 1000 AND LBL 46 THROUGH LBL 49 Z=0 THROUGH Z=-2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED.