What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE 'A' PIT TIE DOWN SUPPORT PLATE AT STA 280 AND L32R TO L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SUPPORT IAW DC-8 SRM 51-3-0 AND DWG 5751568.