What was found
DURING A MAINTENANCE VISIT FOUND A WORN SEAT TRACK AT FE'S STA IN COCKPIT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-24, 51-1-12 AND 51-1-5.