What was found
DURING A MAINTENANCE VISIT FOUND A WORN SEAT TRACK AT STA 950-957 BL-0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW PART IAW DC-8 SRM 53-2-3 FIG 8A, 51-1-20, 51-1-24, 51-3-0, 51-9-0 AND 51-1-20 FIG 4A.