What was found
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE SUPPORT FITTING ON THE R/H I/B CARGO TRACK AT STA 68X-45.50, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DC-8 SRM 51-1-24 AND 51-1-20D.