What was found
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE LONGERON END AT FS 14 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW PART AND INSTALLED IAW DC-8 SRM 51-1-24.