As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LOWER SIDE OF TOP FLANGE OF FLOOR SUPORT AT CLIP NUTS AT STA Y=1745 AND RBL 23, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 51-1-20 FIG 6 AND 53-2-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).