What was found
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES AND CORROSION DAMAGE TO THE SEAT TRACK BETWEEN STA'S -99 TO -67 X=0 TO -6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-3-0, 51-1-24 AND 53-2-0 FIG 1F.