What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE 9G BULKHEAD PANEL AT STA 70, X=25, Z=15, DAAMGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PANEL IAW DC-8 SRM 53-2-0, 51-1-4.