What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LWR CARGO PIT CEILING SUPPORT AT STA 1390, X=+41 TO -41, Z+-6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21 AND 53-2-0 FIG 1F. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).