SDR RRXA010002

Service difficulty report · Cooler · Doug DC873F

Difficulty date
January 5, 2001
Submitted
January 19, 2001
Operation
Air carrier
Aircraft
N870TV
Make and model
Doug DC873F
Aircraft serial
46086
Aircraft time
83,797 hours, 26,985 cycles
Part
Cooler
Part number
9799084
Part serial
00P517
Condition
Failed
Location
Anti-Ice System
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEFT MANIFOLD AIR TEMP DID NOT EXCEED 170C N1 WERE AT 88 PERCENT, ENGINE ANTI-ICE ON, AIRFOIL DEICE ON, TAIL DEICE SYSTEM ON, THIS IS THE 3RD WRITTEN UP SEE PAGES 7686-24 AND 7686-23 MIN NEED IS 190C NOTE LEFT PACK ON 80 PERCENT. REMOVED AND REPLACED NR 1 ENG PRECOOLER CONTROL VALVE IAW DC8 MM 36-12-59 AND REMOVED AND REPLACED NR 1 ENG PNEU BLEED REG VALVE IAW DC8 MM 36-12-1 ENG RUN ACCOMPLISHED, SYSTEM OPS CHECK NORMAL IAW DC8 MM 36-12-58.