What was found
DURING A MAINTENANCE VIST FOUND ELONGATED HOLE DAMAGE TO SKIN AT FWD OF MLG DOORS, DAMAGE ECXEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 51-3-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A MAINTENANCE VIST FOUND ELONGATED HOLE DAMAGE TO SKIN AT FWD OF MLG DOORS, DAMAGE ECXEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 51-3-0.