What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO STRINGER #76 AT STA. XCW23 AND XCW46 AND INSIDE L/H CENTER WING TANK THRU MID SPAR ACCESS HOLE 560E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-24 AND DC-8 SRM 51-1-20D AND E.O.#01-006 WITH APPROVED 8110-3 DATED 01/22/01. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).