What was found
DURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO FLOOR PANEL BETWEEN TRACKS 1 & 2 AT STA. 480-560, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0 AND DOUGLAS DRAWING #5804513.