DURING A MAINTENANCE VISIT FOUND CORROSION TO BATH TUBE FITTING AT STA. 1690 AND L30R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-21 & 51-1-20D & 51-1-24 & 53-2-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).