What was found
DURING A MAINTENANCE VISIT FOUND A DRILL START TO THE BATHTUB FITTING AT STA 1228 AND L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-20D, 53-1-0 AND DWG 3755845.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A MAINTENANCE VISIT FOUND A DRILL START TO THE BATHTUB FITTING AT STA 1228 AND L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-20D, 53-1-0 AND DWG 3755845.