As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A MAINTENANCE VISIT FOUND A LARGE GAP BETWEEN O/B END FITTING AND BATHTUB FITTING AT FS 1220 AND L33L TO L34L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-20D, 53-1-0 AND DWG 3755845.